New Mexico Patent of the Month – January 2026

 

Quick Summary: U.S. Patent No. 12,520,448 by Nubis Communications has been designated the New Jersey Patent of the Month (January 2026). This innovation introduces a rack-mount thermal design that integrates optical modules with optimized air cooling, enabling 1.6 Tbps interconnects without liquid cooling or DSPs. This breakthrough directly addresses the “energy wall” in AI supercomputing, offering a scalable solution for high-density data centers.

Introduction: Patent Designation and Selection Methodology

U.S. Patent No. 12,520,448, titled “Thermal design for rack mount systems including optical communication modules,” represents a definitive advancement in the critical infrastructure supporting next-generation computing. Applied for on November 19, 2021, and formally granted on January 6, 2026, this intellectual property has been distinguished as the New Jersey Patent of the Month. This selection was not the result of a traditional, manual editorial review, but rather the output of a sophisticated evaluation process utilizing advanced Artificial Intelligence technology. The AI system, deployed to scrutinize the innovation landscape, parsed over 1,000 potential patents granted within the jurisdiction to identify this specific filing as a statistical and technological outlier. By analyzing semantic patterns, citation potential, and claims breadth, the AI algorithms isolated Patent 12,520,448 as a pivotal innovation, elevating it above nearly a thousand contemporaries to receive this prestigious designation.

The selection of this patent as the New Jersey Patent of the Month was driven primarily by its profound real-world impact. While many patents remain theoretical or confined to niche applications, the technology described in Patent 12,520,448 directly addresses the existential “energy wall” and “density paradox” currently threatening the scalability of Artificial Intelligence (AI) and Machine Learning (ML) clusters. As the digital economy transitions toward exascale computing, the physical infrastructure of the data center—specifically the thermal management of high-speed interconnects—has become the primary bottleneck. This patent was chosen because it offers a commercially viable, immediately applicable engineering solution to these constraints, enabling the deployment of 1.6 Terabit-per-second (Tbps) links within standard air-cooled environments. Its selection underscores a recognition that the future of AI does not rely solely on algorithmic breakthroughs, but fundamentally on the physical layer innovations that allow massive computing arrays to communicate without overheating or exceeding power budgets.


Technical Superiority and Competitive Benchmarking

The optical interconnect market is currently defined by a fierce tripartite struggle between three architectural philosophies: Pluggable Optics (the incumbent), Co-Packaged Optics (the integrated challenger), and Linear Drive Optics (the simplified, efficient contender represented by Nubis Communications and this patent). To understand the superiority of Patent 12,520,448, one must dissect the limitations it overcomes in rival approaches.

The Core Innovation: Solving the Thermal-Density Nexus

The patent claims a “rackmount device” with specific dimensional constraints (width of 16 to 20 inches) that integrates optical communication modules. While this may appear to be a simple form-factor specification, it is in fact a strategic claim that protects a novel thermal architecture. High-performance optical engines, such as the Nubis XT1600 supported by this patent, generate significant heat flux density. In traditional designs, this heat is managed inefficiently, requiring either massive airflow (which creates noise and vibration that can disturb optical alignment) or liquid cooling (which introduces infrastructure complexity and leak risks).

The superiority of the technology described in Patent 12,520,448 lies in its integrated thermal-optical co-design. Unlike competitors who design the optics and the chassis in isolation, this patent treats the optical module and its thermal enclosure as a single, unified system. This holistic approach allows for:

  1. Laminar Airflow Optimization: The housing design minimizes turbulence and back-pressure, allowing for efficient heat extraction from the dense optical arrays using standard fans running at lower RPMs.
  2. DSP-Free Operation: The thermal stability provided by this specialized housing is the key enabler for “Linear Drive” optics. Linear drive architectures remove the Digital Signal Processor (DSP) from the optical module to save power and latency. However, without a DSP to electronically compensate for signal impairments, the optics must be incredibly stable. The patent’s thermal design ensures the laser and modulator remain in their optimal operating window solely through physical thermal management, eliminating the need for power-hungry electronic correction.

Competitive Benchmarking

The following analysis benchmarks the technology protected by Patent 12,520,448 against the primary market alternatives: Broadcom (Co-Packaged Optics), Ayar Labs (Remote Laser Source), and Standard Pluggables (QSFP-DD/OSFP).

Nubis (Patent 12,520,448) vs. Broadcom (Bailly / CPO)

Broadcom is a formidable competitor, championing a Co-Packaged Optics (CPO) strategy where the optical engine is bonded directly to the switch ASIC substrate.

  • Thermal Management: Broadcom’s approach concentrates an enormous amount of heat (ASIC + Optics) into a single, small footprint. This heat density often necessitates liquid cooling or elaborate heat pipes, raising the total cost of ownership (TCO) for data center operators.
  • Nubis Superiority: Patent 12,520,448 enables a “Near-Package” or distributed architecture where the optical engines are close to the ASIC but thermally decoupled. The patent’s rack-mount design allows these components to be spread out just enough to utilize high-efficiency air cooling, avoiding the “thermal runaway” risks of monolithic CPO.
  • Ecosystem Openness: Broadcom’s solution is vertically integrated and proprietary.
  • Nubis Superiority: The patent describes a rack-mount system compatible with standard dimensions. This supports an open ecosystem where the Nubis optical engine can be paired with various ASICs (e.g., from Marvell or Nvidia), offering hyperscalers the flexibility they demand.

Nubis (Patent 12,520,448) vs. Ayar Labs (TeraPHY™)

Ayar Labs utilizes a “remote light source” architecture (SuperNova™), where the laser is housed in a separate rack unit and light is piped in via fiber.

  • Complexity and Reliability: While Ayar’s approach removes the heat source (laser) from the processor, it introduces a massive web of polarization-maintaining fibers. Every connector is a potential point of failure and signal loss.
  • Nubis Superiority: The technology in Patent 12,520,448 keeps the laser integrated within the rack-mount module but manages its heat in situ. This eliminates the “fiber spaghetti” of remote laser sources. The patent’s thermal design ensures the local lasers operate reliably, providing the simplicity of a transceiver with the performance of CPO.
  • Latency: The remote laser architecture adds time-of-flight latency.
  • Nubis Superiority: By keeping the entire optical-electrical conversion process contained within the claimed rack-mount unit, Nubis minimizes latency—critical for the synchronization of billion-parameter AI training runs.

Nubis (Patent 12,520,448) vs. Standard Pluggables (The Status Quo)

The incumbent technology involves plugging modules (like QSFP-DD) into the front panel.

  • Density and Reach: Pluggables are limited by the physical space on the faceplate (beachfront). As speeds hit 1.6T and 3.2T, the faceplate simply runs out of room. Furthermore, the electrical signal must travel from the ASIC to the faceplate across the PCB, incurring heavy losses (requiring re-timers).
  • Nubis Superiority: The patent enables high-density optical engines to be placed inside the rack (mid-board), bypassing faceplate limitations. This allows for 10x the bandwidth density (500 Gbps/mm vs. ~50 Gbps/mm for pluggables) and significantly shorter electrical traces, which is the physical basis for the patent’s power efficiency claims.

Summary of Superiority Metrics

Metric Nubis Communications (Patent 12,520,448) Standard Pluggables (QSFP-DD) Co-Packaged Optics (Broadcom) Remote Laser CPO (Ayar Labs)
Power Efficiency < 4 pJ/bit (Industry Leading) ~12-15 pJ/bit ~5-8 pJ/bit ~3-5 pJ/bit
Cooling Method Optimized Air Cooling (Patent Focus) Standard Air Cooling Liquid Cooling Often Required Air/Liquid Mix
Latency Ultra-Low (No DSP) High (DSP Required) Medium (Retimer) Low
Density 500 Gbps/mm ~50 Gbps/mm High (ASIC Limited) High
Infrastructure Impact Low (Fits Standard Racks) Low High (Liquid/Power Density) High (Cabling Complexity)

Real-World Impact and Future Potentials

The “real-world impact” citation for the New Jersey Patent of the Month award is validated by the immediate and transformative application of this technology in the global data infrastructure.

Unlocking the AI Supercomputer

The primary bottleneck in modern AI supercomputers is not computation (FLOPS) but communication (Bandwidth). When training a Large Language Model (LLM) like GPT-5, thousands of GPUs must exchange petabytes of data in real-time. If the network is slow, expensive GPUs sit idle.

  • Impact: The technology in Patent 12,520,448 allows for the construction of “Scale-Up” fabrics that are significantly denser and more power-efficient. By reducing the power cost of moving data from 15 pJ/bit to under 4 pJ/bit, Nubis effectively frees up megawatts of power capacity in a data center. This “reclaimed” power can then be used to add more GPUs, directly increasing the computational capacity of the facility without building new power plants.
  • Economic Valuation: This efficiency is why Ciena, a global telecommunications giant, moved to acquire Nubis Communications for $270 million. The patent is not just an engineering schematic; it is the cornerstone of a nine-figure business valuation, proving its commercial viability.

Extending the Life of Air-Cooled Infrastructure

The majority of the world’s data centers are designed for air cooling. Retrofitting these facilities for liquid cooling (to support competitors like Broadcom CPO) is prohibitively expensive and operationally disruptive.

  • Impact: By patenting a thermal design that enables extreme density within an air-cooled paradigm, Nubis allows legacy data centers to participate in the AI boom. This democratizes access to high-performance computing, allowing smaller operators to host AI inference clusters without needing a complete facility overhaul.

Future Potentials: 6G and Edge Computing

While currently focused on the data center, the “thermal design for rack mount systems” has profound implications for the future of telecommunications, specifically 6G.

  • 6G Radio Access Networks (RAN): Future 6G towers will require terabits of data throughput at the edge. However, cell towers have strict power and space limits and cannot support liquid cooling. The Nubis patent’s focus on compact, thermally efficient, maintenance-free optical enclosures makes it the ideal candidate for 6G “fronthaul” links. A demonstration with Ericsson has already highlighted this potential, proving the technology’s versatility beyond the server farm.
  • Aerospace: The high density-to-weight ratio of the Nubis optical engine is critical for avionics and satellite constellations, where every gram of weight and watt of heat dissipation is a constraining factor.

Strategic R&D Tax Credit Analysis: Navigating the Four-Part Test

The development of the technology described in Patent 12,520,448 is a quintessential example of innovation eligible for the Research & Development (R&D) Tax Credit. For companies engaging in similar hardware engineering challenges, understanding how this specific project aligns with the IRS Four-Part Test is crucial for maximizing financial returns. Swanson Reed, utilizing their proprietary AI platform TaxTrex, specializes in substantiating such claims.

The Four-Part Test Applied to Patent 12,520,448

To qualify for the federal R&D tax credit under IRC Section 41, the activities undertaken by the Nubis inventors (Sawyer, Zhang, Winzer, et al.) must satisfy four specific criteria.

Test 1: Permitted Purpose

Requirement: The activity must relate to a new or improved business component (product, process, software, formula, or invention) with the intent to improve functionality, performance, reliability, or quality.

  • Application: The project’s goal was to create the XT1600 Optical Engine and its associated Rack-Mount Thermal Housing. This is undeniably a new business component.
  • Nubis Case: The “Permitted Purpose” was to improve performance (achieving 1.6 Tbps bandwidth), reliability (maintaining laser wavelength stability across wide temperature ranges), and quality (reducing bit error rates without DSPs). The patent documentation itself serves as proof of this intent, describing the specific functional improvements over prior art.

Test 2: Elimination of Uncertainty

Requirement: At the outset, there must be uncertainty regarding the capability to develop the component, the method of development, or the appropriate design.

  • Application: It is not enough to face a difficult task; the team must face technical unknowns.
  • Nubis Case:
    • Uncertainty of Capability: Could 16 lanes of 100G optics be cooled purely by air in a 1RU form factor without thermal crosstalk?
    • Uncertainty of Design: What is the optimal shape of the internal airflow baffles? What material composition (copper vs. aluminum alloys) provides the necessary thermal conductivity while maintaining structural integrity for rack mounting? The patent’s specific claims regarding dimensions (16-20 inches) and configurations suggest these were the variables the team had to determine.

Test 3: Process of Experimentation

Requirement: Substantially all of the activities must constitute elements of a process of experimentation involving the systematic evaluation of alternatives.

  • Application: This is the core “scientific method” requirement.
  • Nubis Case: The engineering team likely employed:
    • Simulation: Running Computational Fluid Dynamics (CFD) models (e.g., Ansys Icepak) to predict airflow and thermal gradients.
    • Prototyping: Fabricating multiple “looks-like/works-like” chassis prototypes to physically test thermal resistance.
    • Iterative Testing: Subjecting these prototypes to thermal chambers, measuring optical performance at T-max and T-min, identifying failure points (e.g., laser drift), and refining the design. This cycle of Hypothesis -> Test -> Analyze -> Refine is the definition of a qualifying process.

Test 4: Technological in Nature

Requirement: The process of experimentation must fundamentally rely on principles of the hard sciences (engineering, physics, biology, computer science).

  • Application: Soft sciences (economics, consumer preference) do not qualify.
  • Nubis Case: The development relied heavily on Thermodynamics (heat transfer coefficients, convection), Optical Physics (photon propagation, laser characteristics), and Materials Science (thermal expansion matching). The patent describes a “Thermal design,” which is inherently grounded in physical engineering principles.

How Swanson Reed Helps Claim the Credit

Navigating the documentation requirements for these tests is the primary hurdle for engineering firms. Swanson Reed streamlines this process through a combination of AI technology and expert review.

The “TaxTrex” AI Advantage

Swanson Reed utilizes TaxTrex, an AI-driven platform referenced in the “Patent of the Month” selection process. For a complex hardware project like the Nubis thermal housing, TaxTrex offers critical advantages:

  • Real-Time Substantiation: The biggest risk in R&D claims is “hindsight bias”—trying to recall specific testing failures months or years later. TaxTrex surveys engineers during the project (e.g., integrating with Jira or Slack) to capture technical challenges as they arise. It creates a timestamped audit trail of the “Uncertainties” and “Experiments” (Test 2 and Test 3).
  • Automated Expense Tracking: The AI scans financial ledgers to tag Qualified Research Expenses (QREs) such as:
    • Wages: Salaries of the optical engineers and thermal architects.
    • Supplies: Costs of prototypes, thermocouples, and silicon wafers used in destructive testing.
    • Cloud Compute: Costs for running the CFD thermal simulations.
  • Speed: TaxTrex allows companies to generate a compliant technical report and claim calculation in as little as 90 minutes, making the credit accessible even to lean startups.

The “Six-Eye Review” and Audit Defense

While AI handles data collection, Swanson Reed applies a “Six-Eye Review” process to ensure defensibility:

  1. Technical Review: A qualified engineer reviews the narrative to ensure the physics described aligns with the “Technological in Nature” requirement.
  2. Legal Review: A tax attorney ensures the claim methodology aligns with recent Tax Court rulings.
  3. Financial Review: A CPA validates the QRE calculations.

Furthermore, via their CreditARMOR service, Swanson Reed provides audit defense. In the case of Patent 12,520,448, if the IRS questioned the claim, Swanson Reed would utilize the patent filing itself, along with the prototype logs and simulation data captured by TaxTrex, to conclusively prove that the project met all statutory requirements.


Detailed Technical Analysis: The Engineering Behind the Patent

Context: The Evolution of Data Center Interconnects

To fully appreciate the scope of Patent 12,520,448, it is necessary to examine the trajectory of data center interconnects. For decades, the industry relied on Non-Return-to-Zero (NRZ) signaling, where a simple “on” or “off” represented a 1 or 0. As bandwidth demands grew, the industry shifted to Pulse Amplitude Modulation 4-level (PAM4), which encodes two bits per symbol.

While PAM4 doubled the bandwidth, it significantly reduced the signal-to-noise ratio (SNR). This necessitated the introduction of powerful Digital Signal Processors (DSPs) inside every optical transceiver to clean up the signal. These DSPs, while effective, became a parasite. Today, a standard 800G optical module consumes roughly 14-16 Watts, with nearly half of that power burned by the DSP. In a 1RU switch with 32 ports, the optics alone can consume 500 Watts, creating a thermal density that is difficult to manage.

The Nubis Innovation: Removing the Parasite

The core philosophy behind the Nubis patent is “Linear Drive.” The concept is simple but difficult to execute: remove the DSP from the optical module. By connecting the switch ASIC directly to the optical engine via a linear analog channel, the power consumption drops dramatically—from ~15 Watts per module to ~4-5 Watts.

However, removing the DSP removes the safety net. The DSP can electronically compensate for temperature-induced drift in the laser or modulator. Without it, the optics must be thermally perfect. This is where Patent 12,520,448 becomes critical. It is not just a box; it is a precision thermal instrument.

Anatomy of the Invention

The patent describes a system comprising several key subsystems:

  1. The Rackmount Chassis: Defined by the 16-20 inch width, this chassis is engineered to interface with standard 19-inch racks (EIA-310 standard). The “1-12 inch” height range covers standard 1U, 2U, and 4U configurations.
  2. The Optical Engine Carrier: The patent details how the optical modules are mounted. Unlike faceplate pluggables, these modules are likely mounted on the main PCB or on a mezzanine card (Near-Package Optics). This placement shortens the electrical trace length to the ASIC, which is essential for Linear Drive operation.
  3. The Airflow Director: The internal geometry of the housing is shaped to create specific pressure zones. The design likely employs “ducted” cooling, where fresh air is channeled directly over the optical engine heat sinks before it is warmed by other components like the CPU or power supply. This ensures the optics always receive the coolest possible air (inlet temperature).
  4. Thermal Isolation Barriers: To prevent “thermal cross-talk”—where heat from one module affects a neighbor—the patent likely describes the use of thermal breaks or insulative materials between high-density clusters.

Technical Challenges Overcome

The “Elimination of Uncertainty” aspect of the R&D process highlights the difficulty of this design:

  • Heat Flux Density: A 1.6T optical engine packs incredible power into a footprint the size of a fingernail. Conducting this heat away to the fins of a heatsink without a high thermal resistance penalty is a significant materials science challenge.
  • Aerodynamic Impedance: High-density fins provide better cooling surface area but block airflow (high impedance). The patent solves the optimization problem of finding the perfect fin geometry that maximizes cooling while minimizing the pressure drop, allowing standard fans to push enough air through the chassis.

Detailed Competitive Landscape and Market Analysis

The “Energy Wall” Market Driver

The global data center industry is facing an energy crisis. Data centers currently consume roughly 2-3% of the world’s electricity, but this is projected to triple by 2030 due to the AI boom.

  • The Problem: Moore’s Law is slowing down for efficiency. We are no longer getting “free” power reduction with every node shrink.
  • The Solution: The only way to continue scaling is to address the I/O power. If the network consumes 30-40% of the cluster’s power (a common metric in AI training), reducing that by 75% (via the Nubis 4 pJ/bit metric) has a massive impact on the Total Cost of Ownership (TCO).

Competitor Deep Dive

Broadcom

Broadcom is the market leader in switching silicon (Tomahawk, Jericho). Their CPO strategy is defensive—they want to integrate the optics to keep the value chain in-house.

  • Strength: Massive manufacturing scale and deep pockets.
  • Weakness: Their solution is a “walled garden.” If a hyperscaler uses Broadcom CPO, they are locked into the Broadcom ecosystem for everything. The thermal concentration of their CPO solution also makes it difficult to deploy in older, air-cooled facilities.

Marvell / Inphi

Marvell is the leader in DSPs (the component Nubis is trying to eliminate). They are pushing “Linear Drive Pluggables” (LPO), which keep the standard form factor (QSFP) but remove the DSP.

  • Comparison: Nubis’s approach (Patent 12,520,448) is superior to Marvell’s LPO because standard pluggables are still limited by faceplate density. Marvell can make the module lower power, but they can’t make the faceplate bigger. Nubis moves the optics inside, solving the density problem that Marvell cannot address with standard form factors.

Intel Silicon Photonics

Intel has shipped millions of CWDM4 transceivers. However, their technology is based on Indium Phosphide (InP) bonding which has historically had yield challenges.

  • Comparison: Nubis uses a “pure” Silicon Photonics approach with a novel 2D fiber array (as described in their broader IP portfolio and supported by this packaging patent). This allows for higher manufacturing yields and lower costs compared to Intel’s complex hybrid integration.

The Ciena Acquisition: A Strategic Signal

The acquisition of Nubis by Ciena is a watershed moment. Ciena is traditionally a “Long Haul” and “Metro” optical company (connecting cities). Buying Nubis (a “Short Reach” inside-the-data-center company) signals that the distinction between Telecom and Datacom is blurring.

  • Strategic Fit: Ciena can now offer an end-to-end solution. They can connect the data centers together (using their WaveLogic coherent optics) and connect the servers inside the data center (using Nubis linear optics).
  • Validation: Ciena’s due diligence would have rigorously scrutinized the patent portfolio. Their $270M investment confirms that Patent 12,520,448 provides effective blocking claims that protect their competitive advantage in the AI era.

Broader Economic and Environmental Implications

Economic Efficiency

For a Hyperscaler (e.g., Google, Microsoft, Meta), the cost of building an AI cluster is measured in billions.

  • CAPEX Savings: By using Nubis’s technology, they can avoid the massive capital expenditure of retrofitting data centers for liquid cooling.
  • OPEX Savings: The 4x power reduction translates directly to the electricity bill. Over the 3-5 year life of a supercomputer, this saves millions of dollars.

Sustainability and Carbon Footprint

The AI industry is under pressure to reduce its carbon footprint.

  • Green Computing: Technology that reduces power consumption is “Green Technology.” Patent 12,520,448 is an enabler of sustainable AI. By allowing more computation per watt, it directly reduces the carbon intensity of training Large Language Models.
  • Regulatory Compliance: As governments (like the EU) introduce strict efficiency standards for data centers, technologies like Nubis’s will transition from “nice-to-have” to “regulatory necessity.”

Final Thoughts: The Indispensable Innovation

U.S. Patent No. 12,520,448 is more than a technical document; it is a blueprint for the sustainable expansion of the Artificial Intelligence economy. By solving the prosaic yet profound challenges of thermal management and packaging density, Nubis Communications has cleared the path for the next generation of supercomputers.

The “New Jersey Patent of the Month” award, identified through the precision of AI analysis, rightly recognizes this patent as a cornerstone of modern infrastructure. It is superior to its competitors because it offers a pragmatic, scalable, and non-disruptive path to extreme performance—avoiding the proprietary lock-in of Co-Packaged Optics and the complexity of remote lasers.

For the engineering community, this patent serves as a masterclass in multidisciplinary design—harmonizing thermodynamics, optics, and mechanics. For the financial community, the Ciena acquisition serves as proof of the immense value creation possible when deep-tech innovation is protected by robust intellectual property. And for the corporate strategist, the alignment of this project with the R&D Tax Credit—substantiated by tools like Swanson Reed’s TaxTrex—demonstrates how smart fiscal policy can subsidize the very risks that lead to such breakthrough technologies. As the “energy wall” looms, Patent 12,520,448 stands as a critical breach, allowing the digital revolution to march forward, cooler, faster, and more efficient than ever before.

Who We Are:

Swanson Reed is one of the largest Specialist R&D Tax Credit advisory firm in the United States. With offices nationwide, we are one of the only firms globally to exclusively provide R&D Tax Credit consulting services to our clients. We have been exclusively providing R&D Tax Credit claim preparation and audit compliance solutions for over 30 years. Swanson Reed hosts daily free webinars and provides free IRS CE and CPE credits for CPAs.

Are you eligible?

R&D Tax Credit Eligibility AI Tool

Why choose us?

R&D tax credit

Pass an Audit?

R&D tax credit

What is the R&D Tax Credit?

The Research & Experimentation Tax Credit (or R&D Tax Credit), is a general business tax credit under Internal Revenue Code section 41 for companies that incur research and development (R&D) costs in the United States. The credits are a tax incentive for performing qualified research in the United States, resulting in a credit to a tax return. For the first three years of R&D claims, 6% of the total qualified research expenses (QRE) form the gross credit. In the 4th year of claims and beyond, a base amount is calculated, and an adjusted expense line is multiplied times 14%. Click here to learn more.

Never miss a deadline again

R&D tax credit

Stay up to date on IRS processes

Discover R&D in your industry

R&D Tax Credit Preparation Services

Swanson Reed is one of the only companies in the United States to exclusively focus on R&D tax credit preparation. Swanson Reed provides state and federal R&D tax credit preparation and audit services to all 50 states.

If you have any questions or need further assistance, please call or email our CEO, Damian Smyth on (800) 986-4725.
Feel free to book a quick teleconference with one of our national R&D tax credit specialists at a time that is convenient for you.

R&D Tax Credit Audit Advisory Services

creditARMOR is a sophisticated R&D tax credit insurance and AI-driven risk management platform. It mitigates audit exposure by covering defense expenses, including CPA, tax attorney, and specialist consultant fees—delivering robust, compliant support for R&D credit claims. Click here for more information about R&D tax credit management and implementation.

Our Fees

Swanson Reed offers R&D tax credit preparation and audit services at our hourly rates of between $195 – $395 per hour. We are also able offer fixed fees and success fees in special circumstances. Learn more at https://www.swansonreed.com/about-us/research-tax-credit-consulting/our-fees/

R&D Tax Credit Training for CPAs

R&D tax credit

Upcoming Webinars

R&D Tax Credit Training for CFPs

bigstock Image of two young businessmen 521093561 300x200

Upcoming Webinars

R&D Tax Credit Training for SMBs

water tech

Upcoming Webinars
Recent Posts